Find Jobs
Hire Freelancers

Allen Bradley CompactLogix PLC and Automation Direct programming

$25-50 USD / hour

クローズ
投稿日: 11年近く前

$25-50 USD / hour

Write programs for an Allen Bradley CompactLogix PLC and an Automation Direct OIU. Context below. Specifics will be provided following the selection of a skilled programmer and sign off on appropriate documentation - e.g. - contract, non disclosure agreement, etc. Each product may be operated either manually or automatically. Operating mode is chosen for each product independently using a four position selector switch (A-B-C-D) provided for each product (ten total) on the door of the control panel mounted on the HPU. A product operating in the A mode will be automatically modulated to control input elevation to the desired (preprogrammed) setpoint. So that all the products operating in this mode are as close as possible to the same elevation, if the control must lower a product to maintain input elevation, the product with the highest product elevation will be lowered. Similarly, if the control must raise a product to maintain input elevation, the product with the lowest product elevation will be raised. A product operating in the B mode will be automatically modulated to keep the product elevation a fixed distance below the input elevation. All products operating in the B mode will be maintained at the same elevation. Each product operating in the C mode will be automatically modulated to keep the product elevation at a fixed preset elevation. This preset elevation can be entered independently by operating personnel for each product through the OIU/HMI. Each product operating in the D-manual mode can be positioned at the fully lowered (open), fully raised (closed), or any intermediate position independently from other products through the use of dedicated CLOSE and OPEN pushbuttons provided for each product in the door of the remote control station or the control panel mounted on the HPU. The active control location is determined independently for each product by the position of the LOCAL-REMOTE selector switches, one for each product, ten total, in the door of the control panel on the HPU. Actuating the CLOSE or OPEN pushbutton will cause motion in the selected direction until the pushbutton is released or the end of product travel is reached. Whenever product movement is required, one of the two hydraulic pump motors is started. The two pumps alternate duty each time a pump start is required. Should one of the pumps fail to produce flow as measured by a flow switch, a GENERAL ALARM will be indicated and the other pump will be automatically started. The pumps do not run simultaneously.
プロジェクト ID: 4549545

プロジェクトについて

1個の提案
リモートプロジェクト
アクティブ 11年前

お金を稼ぎたいですか?

Freelancerで入札する利点

予算と期間を設定してください
仕事で報酬を得る
提案をご説明ください
登録して仕事に入札するのは無料です

クライアントについて

UNITED STATESのフラグ
United States
0.0
0
メンバー登録日:5月 23, 2013

クライアント確認

ありがとうございます!無料クレジットを受け取るリンクをメールしました。
メールを送信中に問題が発生しました。もう一度お試しください。
登録ユーザー 投稿された仕事の合計
Freelancer ® is a registered Trademark of Freelancer Technology Pty Limited (ACN 142 189 759)
Copyright © 2024 Freelancer Technology Pty Limited (ACN 142 189 759)
プレビューを読み込み中
位置情報へのアクセスが許可されました。
あなたのログインセッションの有効期限がきれ、ログアウトされました。もう一度ログインしてください。